I tried to ask this question via the contact form on the Alphason website but apparently I'm not human so my submission was rejected. What are the criteria for choosing which weight of cartridge stabiliser to use?
We have had some problems with the website and looking into this. You can e-mail me directly: mike (dot) k (at) .....
The traditional formula is flawed as it assumes the cartridge suspension is a simple spring, where it is an elastomer with more complex characteristics.
The best performance may be obtained by using the formula as a guide to establish a starting point, then empirically iterating. However, the formula is flawed and so it pays to experiment. I was very surprised that a 35mm/N compliance cartridge performed best, without mis-tracking, when I added a further 1x12g plus 1x8g plus 1x 2g Stablisers. The formula predicted that no mass should be added if mis-tracking was to be avoided. How wrong could it be? Experimenting opened up a whole new listening experience. I was amazed to hear what was possible.
The traditional formula is as follows: f = 1000 / (2 x π x √ (M + C))
Where:
f is the cartridge/total effective mass resonance in Hz
π is 3.14159
C is cartridge compliance in µm/mN or mm/N or cm/dyne x 10E-6 or CU
M is the total effective mass which is the sum of the tonearm effective mass + the mass of the cartridge + the mass of fixings and finger grip etc + the mass of Stabilisers
We have found that a theoretical resonance frequency, f, of around 6.5Hz is a good place to start. The theoretical mass of Stabilisers to be added may be found by re-arranging the formula
M = ((1000 / (2 x π x f))^2 ) / C
and substituting 6.5Hz for f becomes
M = ((1000 / 2 x π x 6.5))^2) / C
or
M = 618.4 / C
So if the compliance is 16, then total effective mass is 618.4 / 16 which is 38.65g
If the cartridge weighs 9.5g, fixing screws weigh 0.5g and the tonearm effective mass is 12.5g then the mass of Stabilisers required as a starting point is 38.65 - 9.5 - 0.5 -12.5 = 16.15g ie 2x 8g Stabilisers
We (including fellow enthusiasts) have found that using f = 6.5Hz normally does not lead to mis-tracking. Some enthusiasts settle for this and do not take the trouble or expense to iterate to establish the maximum performance by adding more Stabilisers until mis-tracking is encountered on a mildly warped record, then removing one of the Stabilisers to provide a margin of safety against mis-tracking.
With very low compliance cartridges ie 5 to 10 µm/mN compliance the theoretical mass of Stabilisers required can be 40g to 100g. 100g is not practical and so in this case most enthusiasts use 3x 12g or 4x 12g as the maximum mass of Stabilisers. We have found that some of the Koetsu cartridges with compliance of 5 µm/mN benefit by having the maximum practical mass of Stabilisers.
The thickness of the 8g Stabiliser is 1.7mm and the 12g is 2.4mm. The tonearm must be raised to accommodate the thickness of the Stabilisers and maintain the correct VTA. The tracking force is as recommended by the cartridge manufacturer.
"Add On" counterweights are available to balance the added mass and we also provide a service of making bespoke counterweights.
With high compliance cartridges where the traditional formula predicts that no additional mass should be added, then it is best to try adding Stabilisers until mis-tracking is encountered on a mildly warped record, then removing one Stabiliser to provide a margin against mis-tracking.
We are constantly being surprised by how mis-leading the traditional formula is and day by day we are becoming more and more convinced that the best approach is to empirically maximise the number of Stabilisers, limited by the thickness of Stabilisers and the practical ability to increase the counterweight.
If the effective mass of the tonearm, say 12.5g, + fixings, say 0.5g, + cartridge mass, say 9.5g giving a total of 22.5g has 20g of Stabilisers added ie 89% of the total effective mass before Stabilisers were added, then adding a further 20g provides approximately an additional 47% benefit. A further 20g on top of this provides approximately an additional 32% of benefit. Much of the improved control of the cartridge body resonances and head shell resonances are realised by using a small number of Stabilisers. The additional benefit by using additional Stabilisers does not only include the additional mass damping and stabilising of the cartridge relative to the groove but also the benefits from additional vibrational energy dissipation.
For an Audio-Technica OC5 with a compliance of 35 µm/mN this surprisingly turned out to be 1x 12g then 1 x 2g Stabiliser then 1 x 8g Stabiliser ie 22g in total. The Stabilisers are not just "head shell weights". Far from it. They use the additional mass to not only provide mass damping but also three other vibrational energy dissipation mechanisms whilst providing direct coupling. They not only stabilise the cartridge relative to the groove, for the first time in history, but they also dissipate unwanted vibrational energy, significantly reducing the vibrational energy transmitted into the head shell, arm tube, counter weights, arm mounting board, turntable sub-chassis, suspension springs etc. They also help to control the resonances in the cartridge body and also help to control the resonances in the head shell. There is an awful lot of advanced physics and engineering in these apparently simple Stabilisers!
One of each Stabiliser ie 12g + 2g + 8g or even a 12g and 8g probably provide best perceived value for money. However, enthusiasts who persevere and add as many as possible state that it is the best upgrade they have ever made and "it is like buying a super tonearm but without the associated price tag" So it is up to each individual to decide what is the "best value for money". We support fellow enthusiasts as best as we can by supply of Stabilisers for a 30 day sale or return home trial to assess for themselves what is the best value for money for their application. We support each enthusiast through their evaluation and help them to overcome any obstacles ie by making bespoke components to fit a Zeta counterweight, or a special counterweight for a uni-pivot tonearm or for an SME tonearm etc.
I hope this has helped to clarify how to determine how many Stabilisers to use and why?
Apologies if the website communication channel has failed. We will endeavour to address this issue as soon as possible.
Enjoy your listening experiences.