Alan Oscroft
[SAFETY WARNING: I talk about measuring mains with a multimeter, which can be dangerous. I always make sure everything is switched off before I connect the probes, always use insulated crocodile clip probes (and never poke around with pointy ones), and never touch the probes or the meter when the power is on.]
 
I've been trying to measure any mains DC offset I might have, and I don't seem to be having much success. But let me start at the beginning...
 
I have an Audiolab amp, and its transformer used to buzz, and I thought it might be down to mains DC offset/asymmetry. But I couldn't measure anything just with my meter on the mains, though I guess 240VAC can mess up any chance of measuring DC millivolts with my meter.
 
I built a DC blocker (using Rod Elliott's design), and that solved it. Buzzing from the amp transformer without the blocker, silence with it. Must be DC, then.
 
I still wanted to measure the DC, and it struck me I should be able to do it by measuring across the live in and live out connections inside the blocker (across the capacitor/diode network). It's not across live and neutral, so I surely shouldn't see any VAC. And if there's any DC being blocked, I should be able to see the difference.
 
But when I try, I see a fluctuating DC of only around 5mV, which surely shouldn't be anywhere enough to buzz the transformer.
 
So, not sure exactly what I'm asking, but does any of this make sense? Has anyone here successfully measured mains DC offset? Might it just be that my multimeter can't do it (I tried two, same result with each)? Should I stop obsessing over it and just enjoy the music?
Reply 0 0
jazid
In answer to your last question, yes.
 
As I understand it DC is not some skew in a perfect.waveform, like a sine wave offset by.a few volts. It is caused by distortion and might be better understood as asymmetric positive and negative halves of the same waveform. Integrate the two and the DC offset is revealed.
 
If you look at an oscilloscope mains waveform this will become plainly apparent (don't do this without a suitably attenuated differential probe and/or a maths capable scope or there will be tears!). This integration is a BIG ask for even a decent RMS multimeter, which will typically have a spec stating the limit of its tolerance for asymmetry for measuring RMS AC (crest factor) but not for the DC component within AC.
 
So, long story short, don't bother! If it works enjoy the success and as a plus avoid messing with mains and multimeters. 
Reply 2 0
Rabski
In answer to your last question, yes.
 
As I understand it DC is not some skew in a perfect.waveform, like a sine wave offset by.a few volts. It is caused by distortion and might be better understood as asymmetric positive and negative halves of the same waveform. Integrate the two and the DC offset is revealed.
 
If you look at an oscilloscope mains waveform this will become plainly apparent (don't do this without a suitably attenuated differential probe and/or a maths capable scope or there will be tears!). This integration is a BIG ask for even a decent RMS multimeter, which will typically have a spec stating the limit of its tolerance for asymmetry for measuring RMS AC (crest factor) but not for the DC component within AC.
 
So, long story short, don't bother! If it works enjoy the success and as a plus avoid messing with mains and multimeters. 
This. It's called 'DC offset', but the 'offset' is the important part of the description. It's not an ideal term really. James describes it perfectly.
 
You can't measure it by using a normal multimeter across the DC blocker. I would personally also strongly advise against trying, but there's no point anyway, as normal multimeters won't measure anything sensible.
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0
Alan Oscroft
Thanks folks, that all makes sense, and confirms my suspicion that a multimeter just can't do it. I don't have any differential probes, so I'm keeping my old oscilloscope well away from it too.
 
So, yes, just relax and enjoy my buzz-free listening 😁
Reply 1 0
mac72
Thanks folks, that all makes sense, and confirms my suspicion that a multimeter just can't do it. I don't have any differential probes, so I'm keeping my old oscilloscope well away from it too.
 
So, yes, just relax and enjoy my buzz-free listening 😁
Have a look at this , especially  post 4 &10 :
Reply 1 0
Alan Oscroft
Have a look at this , especially  post 4 &10 :
Interesting thread, thanks. It's clearly a trickier thing to measure than I'd imagined - so I'll just leave the thing plugged in and listen 😁
Reply 0 0
Reply