I had one of my little SE 6V6 amps fail yesterday with some smoke and a bright light for a few seconds. Fortunately I was in the room and turned it off. It is running a Shuguang 6V6 tube. Judging by the (moderate) carnage, it looks like the screen grid shorted to the heater... the tube has been running happily for several years, and failed about a minute after turn on.
I am quire paranoid about failures, and do try and put in fuses in sensible places. This amp has a 20mm fuse in the mains which did not blow. I know this fuse is aimed at catastrophic failure protection, non the less.
On some of by bigger amps I like to put in a fuse in the HT of around 100-250mA, probably SF30 size (The type typically used in the vintage equipment)? in the hope it bigger size is less likely to arc over (higher voltage rating). I like to put it as near to the transformer as possible.
Going forwards I think I am going to research the application of fusible resistors in tube circuits. I have found a lot of resistor types (metal film) can take much abuse, glowing brightly for some time before failure, fun things I used to do in my day job, after burning hole in PCB, where as fusible resistors just go open circuit.
The power supply resistor that suffered the most is between the first and second smoothing cap, for the screen grid supply, it still measures 1k.
The enhanced paranoia is because these amps are pretty benign and cool running, and sometimes get left on by mistake whilst I am out. I used to think 6V6s pretty reliable when not stressed, as in this amp.
I am sure some will have noticed that vintage amplifiers have no fuse at all, like the little Pye black box amps I re-engineered recently.
Like transistor amps, making it work is one thing, making it fail safely is another thing all together.
incurable tinkerer