Dave
I had one of my little SE 6V6 amps fail yesterday with some smoke and a bright light for a few seconds. Fortunately I was in the room and turned it off. It is running a Shuguang 6V6 tube. Judging by the (moderate) carnage, it looks like the screen grid shorted to the heater... the tube has been running happily for several years, and failed about a minute after turn on.
I am quire paranoid about failures, and do try and put in fuses in sensible places. This amp has a 20mm fuse in the mains which did not blow. I know this fuse is aimed at catastrophic failure protection, non the less.
On some of by bigger amps I like to put in a fuse in the HT of around 100-250mA, probably SF30 size (The type typically used in the vintage equipment)? in the hope it bigger size is less likely to arc over (higher voltage rating). I like to put it as near to the transformer as possible.
Going forwards I think I am going to research the application of fusible resistors in tube circuits. I have found a lot of resistor types (metal film) can take much abuse, glowing brightly for some time before failure, fun things I used to do in my day job, after burning hole in PCB, where as fusible resistors just go open circuit.
The power supply resistor that suffered the most is between the first and second smoothing cap, for the screen grid supply, it still measures 1k.
The enhanced paranoia is because these amps are pretty benign and cool running, and sometimes get left on by mistake whilst I am out. I used to think 6V6s pretty reliable when not stressed, as in this amp.
I am sure some will have noticed that vintage amplifiers have no fuse at all, like the little Pye black box amps I re-engineered recently.
 
Like transistor amps, making it work is one thing, making it fail safely is another thing all together.
incurable tinkerer
Reply 0 0
stereo coffee
I had one of my little SE 6V6 amps fail yesterday with some smoke and a bright light for a few seconds. Fortunately I was in the room and turned it off. It is running a Shuguang 6V6 tube. Judging by the (moderate) carnage, it looks like the screen grid shorted to the heater... the tube has been running happily for several years, and failed about a minute after turn on.
I am quire paranoid about failures, and do try and put in fuses in sensible places. This amp has a 20mm fuse in the mains which did not blow. I know this fuse is aimed at catastrophic failure protection, non the less.
On some of by bigger amps I like to put in a fuse in the HT of around 100-250mA, probably SF30 size (The type typically used in the vintage equipment)? in the hope it bigger size is less likely to arc over (higher voltage rating). I like to put it as near to the transformer as possible.
Going forwards I think I am going to research the application of fusible resistors in tube circuits. I have found a lot of resistor types (metal film) can take much abuse, glowing brightly for some time before failure, fun things I used to do in my day job, after burning hole in PCB, where as fusible resistors just go open circuit.
The power supply resistor that suffered the most is between the first and second smoothing cap, for the screen grid supply, it still measures 1k.
The enhanced paranoia is because these amps are pretty benign and cool running, and sometimes get left on by mistake whilst I am out. I used to think 6V6s pretty reliable when not stressed, as in this amp.
I am sure some will have noticed that vintage amplifiers have no fuse at all, like the little Pye black box amps I re-engineered recently.
 
Like transistor amps, making it work is one thing, making it fail safely is another thing all together.
Hi Dave
Consider a inline PTC thermistor , these are re-settable and increase resistance to reduce current when temperature rises.
Reply 0 0
Dave
 
Hmm, initially sceptical, use low voltage devices liberally in day job, but it seems there are a limited availability of devices over 500V 🙂 , certainly worth considering. I wonder how they effect the sound quality???
Hi Dave
Consider a inline PTC thermistor , these are re-settable and increase resistance to reduce current when temperature rises.
incurable tinkerer
Reply 0 0
stereo coffee
 
Hmm, initially sceptical, use low voltage devices liberally in day job, but it seems there are a limited availability of devices over 500V 🙂 , certainly worth considering. I wonder how they effect the sound quality???
Hi Dave
Their resistance only comes into operation when temperature rises , so like not there , unless a fault occurs, which is when you want them. Further info here:   https://product.tdk.com/en/techlibrary/applicationnote/howto_ptc-limiter.html  
Applying to limiting turn on in rush current, which maybe why the fault then occurred. https://www.youtube.com/watch?v=YdL99mtDkXs
Reply 0 0
Dave
Hi Dave
Their resistance only comes into operation when temperature rises , so like not there , unless a fault occurs, which is when you want them. Further info here:   https://product.tdk.com/en/techlibrary/applicationnote/howto_ptc-limiter.html  
Applying to limiting turn on in rush current, which maybe why the fault then occurred.
Hi, re sound quality, this is a hifi forum, I was being facetious. Some more rummaging, I have found some higher current resettable for >500 v. I am going to get some on order, but prices seem a bit variable.
incurable tinkerer
Reply 0 0
Rabski
I'd personally not rely on or use any thermistor for transformer secondary protection. Fuses directly in the transformer HT outputs (so always on the AC side) are most reliable, combined with 'easy blow' cathode resistors for a backup.
 
 
Edited to fix dire spelling 😂
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0