David W Harris g8ina
Valve jobbie.... Never worked on one of these yet. I've done Quad II and TVA and Beard, so its going to be a very new experience bringing it up to full spec. Pics when it arrives 🙂 Wish me luck !
Reply 6 0
Mnky
.........
Reply 1 0
Rabski
With all the valves in and a dummy speaker load or speakers connected, you don't want to be seeing more than 315V at the centre tap of each OPT. So that's the downwind side of the 100 ohm sacrificial resistor. The anode connections should all be fairly close voltage, though not identical. Check the cathode voltages. These should all be within a whisker of 10V. You can pretty much ignore the UL tap voltages, though those should also be reasonably similar. When you say the anode voltages differ, the only real question is 'how much by'?
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 2 0
David W Harris g8ina
Thank you Richard 🙂
Reply 0 0
toprepairman
398V DC is definitely way too high.
Reply 1 0
Rabski
398V DC is definitely way too high.
A bit odd too, especially if all the valves are in.
 
Double check on all the HT resistors and measure all the HT voltages further down the chain. If they're all way over, something odd is going on. Could be anything, but check the obvious (all plate resistors correct, nothing open circuit).
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0
David W Harris g8ina
What should the AC out of the mains TX be ?
Reply 0 0
Rabski
One quick point. We haven't noted the possibility that yours is a very early version. These have a higher HT voltage and different transformers (the OPTs have a 43% UL tap, not 25%). Check the output valve grid leak resistors. On the early version, these are 1M (R12 and R13). If it's an early one, then the voltages are even more critical, as they're running the output valves rather 'hot' and close to the limit.
 
If it's a later one (the vast majority are) then as per the schematic, you should have about 280-0-280 at the mains transformer with the circuit running and properly loaded. The early version is 300-0-300. If it's an early one, I'd personally suggest increasing the value of the sacrificial resistor a little, to drop the HT a touch.
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0
David W Harris g8ina
Thanks Richard, yeah the components would indicate the later model, but Im still not convinced of the mains TX.... More checking today. Thanks 
Reply 0 0
David W Harris g8ina
Bum, it IS the earlier version with 300-0-300 mains TX and 43% taps, so I now need to swap the resistors back to 1M and 100k and the cap to 0.1uF. Richard has advised me to drop the HT a little, so Im upping the sacrificial resistor to 120 ohms and see how we go.

Now Im feeling rather disappointed 🙁
Reply 0 0
toprepairman
Even the earlier one shouldn't be that high, maybe 340ish Volts.
Reply 0 0
toprepairman
We're assuming you're measuring it with the valves in and filaments warmed up?
Reply 0 0
David W Harris g8ina
Yep, a good 45 seconds, then this .... and thats even with upping R21 to 270 ohms 🙁leak-stereo-20-edit2.jpg
Reply 0 0
toprepairman
Ok at least 368 is better than the 398 previously quoted.
What are the filament volts?
Reply 0 0
David W Harris g8ina
This is what it sounds like. Not bad, but there's a strange smell from underneath somewhere and the r22 is too hot to touch 
 
Reply 0 0
Rabski
The voltages are about right for an early one. Except, the output from the transformer is very high. It should be 200-0-200 on the early version, and that should give you about 335V on the hot side of the sacrificial resistor and 320V downwind of it. If you need 270R for R21, then the voltage is way too high to start with. I'm not surprised it's getting hot, because it's having to drop far more voltage than normal. I have a suspicion that either someone has replaced the mains transformer with a different one, or (more likely) there is something awry with the voltage setting wiring. Did you check under the transformer bell-ends to look at the input wiring where the voltage selector plug goes? It's not unheard of for bodges to be done there. I'm also assuming you have a proper GZ34 in there and that someone hasn't sneaked oin some solid-state rectification underneath.
 
If everything really is OK, then I'd personally be looking at dropping the voltage on the mains input side. That's going to dissipate a lot less current and heat. It should be necessary though. Something here is not right.
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0
Rabski
This is the schema for the early version. Do a double check on all the component values to make sure....
 
[281995%2F8783427%2Fmceclip0]
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0
Rabski
PS. That's obviously the one for US spec transformer, but everything else is the same for UK market ones.
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0
toprepairman
That's why I asked for the filament Volts, if that is high then either the input select position is wrong as suggested by Richard, or there is a transformer fault (shorted turn?). Either way a bucking transformer would alleviate that.
Reply 2 0
David W Harris g8ina
Thanks again guys, taking the mains TX out today to check wiring. Going to Retrotech at Coventry Sunday so might be on the lookout for a new TX 🙂
Reply 0 0
Rabski
The mains tranformers are probably the weakest bit of a Stereo 20, because they're a bit marginally specced. However, it's rare for one to fail internally short, though I suppose not impossible. Equally, not impossible that someone has had at it at some time in the past and put the voltage tap wiring back wrong, or that two of the connections are shorting, so bypassing one part of the winding. Easy enough to check the internal wiring first. Then the 'cold' side will be obvious and the highest DCR measurement should correspond to the highest voltage setting. There should be some DCR between each and any winding tap. If any measure 0, then there's your problem.
A common mistake that people make when trying to design something completely foolproof is to underestimate the ingenuity of complete fools
Reply 1 0